Report Exchanging Service from CB Report to CNS Report

The neutralizing measure about the CB report of BSMI (Official Journal: No. 093300005922- issued on R. O. C. 93-9-2) enabled customers to exchange an already issued CB report into CNS certified one by testing only for the deviations with CNS and by submitting other necessary documents. In other words, customer can acquire product safety report for Taiwan without new and full applications of product safety test for CNS standard.

JEL arrange and support for above throughout the procedure. Please check the following "Attention at the time of Report Exchange" and contact us.

Attention at the time of Report Exchange

CB Reports issued before June 30, 2005 can be exchanged by this service. CB Reports issued on July 1, 2005 or later are not applicable. For cases as such, full tests for product safety in accordance with CNS standard is necessary.
The products of which reports are exchangeable from CB Report are only as below. CB Report Exchange for products other than following is not acceptable.

  • Information Technology Equipment (ITE)
  • Uninterruptible Power supply (UPS)
  • Data processor and accessories of motor vehicle, Static Converter for communications equipment, and other exchange-type power supply unit
  • ITE with Audio Visual functions

Only the engineer of BSMI accredited laboratory for product safety testing can perform the work for the report exchange. The local JEL tie-up local laboratory for product safety tests are BSMI accredited, of which engineers carry out the report exchange works with responsibility. We have an optional service to let the engineer to visit Japan to carry out the report exchange work. For details, please refer to Engineer Dispatch Service for CB Report Exchange.

Necessary documents for report exchange

  • CB Report
  • Samples (Necessary number of sample units differs by products)
  • Explanation for the differences in a series product
  • Product descriptions in Chinese
  • A drawing and position of logo mark to be attached
  • Photo image of the product (with a scale)
    ¡External view (6 faces)
    ¡Enclosure: Open
    @¡PCB's (Front/Rear: 2 faces)
  • Circuit diagram or wiring diagram
  • CB Artwork or Layout
  • BSMI Certificate for power cable and power supply cable
  • Certificates for important parts

Flow of Report Exchanging

space Customer space JEL space Tie-up Laboratory for Safety
Step1

Applying Exchanging service
*Please fill in the application form for report exchanging service

next Check for engineerfs schedule next Preliminary check of CB Report*1
space space space next space space
Step2 Preparation of necessary documents and product sample next EFix of date for exchanging
EReceipt of necessary information
ECheck for contents and EUT operation
next

ECheck of the CB Report
ETest for the part of Deviation*2
ETranslation to Chinese

space space space next space space
Step3 Receipt of CNS Report next EReturn of CB Report
EReceipt and confirmation of CNS Report
next Completion of CNS Report
  1. We recommend pre-checking of CB Report, because Report Exchange work will smoothly be processed if PDF file of CB Report is presented to the local engineer to go through before the actual exchange procedure.
  2. Several CB Reports do not need tests for the deviation.

Engineer Dispatch Service for CB Report Exchange

We recommend "Engineer Dispatch Service for CB Report Exchange" for the cases that customers need more accurate lead time, or EUT is too large to be transported, by that service an engineer of the accredited laboratory goes to the customer's office to carry out the exchange work there.
On the occasion of an engineer visit to Japan, JEL makes schedule for them to visit plural manufacturers in need of report exchange, therefore it is possible to reduce the cost than inviting an engineer just for your company.
Specifically, please agree with "Engineer Dispatch Service for CB Report Exchange Terms of Use" as below and fill in necessary information for the Inquiry Form:

Engineer Dispatch Service for CB Report Exchange Terms of Use

Reservation procedure

Please submit to us the "Inquiry Form" with necessary information filled in after agreement with the Terms of Use for this service to apply for a reservation of "Engineer Dispatch Service for CB Report Exchange". According to the provided information with the Inquiry Form, we check engineer's availability, arrange the schedule, and then issue a quotation.
If the content is acceptable, customers are to order with an official "Application Form for Report Exchange Service", and JEL will send a confirmation email after fixing the date of reservation and the schedule of an engineer in charge.

Flow to the reservation


Customer space JEL
Fill in the Inquiry Form and submit it to JEL next ECheck of the product
ECheck of engineer' s schedule
space next space
Check and study About the contents next

EAdvice of availability of service
ERough estimation

space next space
Fill in the Application Form for Report Exchanging Service and submit it to JEL next Final confirmation of the schedule and of the engineer in charge of Report Exchanging Service
space next space
Reservation fixed! next Sending a confirmation mail for the reservation
EFix of a concrete schedule
EAssignment of an engineer in charge
Preparation on the day for Engineer Dispatch Service for CB Report Exchange

If you need additional testing, etc., please follow the instructions of the engineer. Please note that it is charged separately for any additional tests.

Cancellation Policy

Please be noted beforehand that when schedule is changed or canceled on account of customers, cancellation rates based on the following policy are applied.

Cancellation Policy of JEL
10`7days prior to the booked date 30%
6`4 days prior to the booked date 50%
3`0 days prior to the booked date 100%

JEL General Disclaimer

Please understand that JEL can not be responsible for the exemplified cases as below:

  1. Departure flight is cancelled or delayed due to natural disaster, act of God, war, armed conflict, labor strike, hijacking or circumstances of airline arranged by the engineer.
  2. Sample unit for additional product safety testing is damaged or ruined

For details please contact to:
yReservation DeskzGeneral Service Bureau / Asia Approval Group
TEL: +81 4 7188 6381
FAX: +81 4 7188 6382
e-mail: otoiawase@jel.co.jp